Ambient conditions
Degree of protection (EN 60529) : | IP 40 |
Humidity : | < 98 % RH , condensing |
Long-term test (transmitter) : | IEC 770 6.3.2 |
Vibration (sinusoidal) (EN 60068-2-6) : | 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min. |
Output signal
Damping : | 0.0 … 30 s , programmable |
Output signal : | 4 … 20 mA , 2-wire |
Accuracy : | < 0.1 % FSR |
Temperature drift : |
|
Load resistance : | R = (U - 8 V)/23 mA |
Resolution : | 12 bit |
Up/Down scaling limits : | 23 mA / 3.5 mA |
Ripple immunity : | 3 Vrms |
Power-up time : | ≤ 10 s |
Power supply : | 8 … 35 V DC |
Reverse polarity protection : | Yes |
Effect of variations in supply voltage : | < 0.01 %/V |
TAG No. : | 15 characters |
Compliance and approvals
EMC : |
|
Namur : | NE21 |
Explosion protection : |
|
Download Broucher : | FlexTop 2202 |
FlexTop 2202
In-head transmitter for CombiTemp- or OEM applications
- Specifically for Pt100
- Input: Pt100 2-, 3- or 4-conductor
- Measuring range -200 ... +850 °C
- More accurate than 0.25 °C
- ATEX explosion protection
- DIN form B housing installation