top of page

Ambient conditions

 

Degree of protection (EN 60529) :IP 40
Humidity :< 98 % RH , condensing
Long-term test (transmitter) :IEC 770 6.3.2
Vibration (sinusoidal) (EN 60068-2-6) :1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.

Output signal

Damping :0.0 … 30 s , programmable
Output signal :4 … 20 mA , 2-wire
Accuracy :< 0.1 % FSR
Temperature drift :
  • < 0.003 %/K , typ.
  • < 0.01 %/K , max.
Load resistance :R = (U - 8 V)/23 mA
Resolution :12 bit
Up/Down scaling limits :23 mA / 3.5 mA
Ripple immunity :3 Vrms
Power-up time :≤ 10 s
Power supply :8 … 35 V DC
Reverse polarity protection :Yes
Effect of variations in supply voltage :< 0.01 %/V
TAG No. :15 characters

Compliance and approvals

EMC :
  • EN 61000-6-2
  • EN 61000-6-3
  • EN 61326-1
Namur :NE21
Explosion protection :
  • ATEX II 1G Ex ia IIC T5/T6
  • ATEX II 3G Ex nA IIC T5
Download Broucher : FlexTop 2202

FlexTop 2202

  • In-head transmitter for CombiTemp- or OEM applications

    • Specifically for Pt100
    • Input: Pt100 2-, 3- or 4-conductor
    • Measuring range -200 ... +850 °C
    • More accurate than 0.25 °C
    • ATEX explosion protection
    • DIN form B housing installation
bottom of page