top of page

Performance characteristics

 

Measuring range :-1 … 68 bar
Min. measuring span :0.05 bar
Max. measuring span :69 bar
Pressure type :
  • Absolute
  • Relative (gauged)
Standard error of measurement (BFSL) :
  • ± 0.04 % FSR , up to 2:1 turndown ratio
  • ± 0.1 % FSR , up to 4:1 turndown ratio
  • Including non-linearity, hysteresis and non-repeatability according BFSL
  • For turndown, multiply this value by the applied turndown ratio
Max. measuring error :
  • ± 0.1 % FSR , up to 2:1 turndown ratio
  • ± 0.25 % FSR , up to 4:1 turndown ratio
  • Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
  • For turndown, multiply this value by the applied turndown ratio
Temperature coefficient :
  • ≤ 0.05 % FSR/10 K , measuring span
  • ≤ 0.05 % FSR/10 K , zero point
Compensated temperature range :-40 … 85 °C
Long term stability :≤ 0.1 % FSR/a , IEC 770 6.3.2
Max. turndown ratio :10 : 1
Rise time (10 ... 90 %) :≤ 0.3 s
Sample time :≤ 0.3 s
Power-up time :< 10 s

Compliance and approvals

Explosion protection :
  • ATEX II 1D Ex ia IIIC T100 °C Da
  • ATEX II 1G Ex ia IIC T5
  • ATEX II 3G Ex nA IIC T5
Download Broucher : PFMH

PFMH

  • Fully welded pressure sensor with hygienic connection and touch screen

    • Flush membrane with 3-A sanitary standards (FDA-compliant) and EHEDG
    • Resistant to all common CIP cleaning media and SIP-capable (150 °C max, < 60 min)
    • Versions available for high media temperatures (200 °C)
    • Built in graphical display (CombiView DFON optional) and programmable by touch screen or with FlexProgrammer 9701
    • Optionally available with additional relays and 4 ... 20 mA with HART
    • Available with optional ATEX approval (4 ... 20 mA output signal)
bottom of page